We now have two
models to choose from |
|
Part # TG-15-D |
0-15 lbs. 0.01
PSI Resolution |
|
Part # TG-1-D |
0-100 lbs. 0.1
PSI Resolution |
SPECIFICATIONS
Storage temperature –40 to 203°F
(–40 to 95°C)
Operating temperature . . . . . . . . . . . . . . . . . . . . . . .
–4 to 185°F (–20 to 85°C)
Compensated temperature . . . . . . . . . . . . . . . . . . . . . .
32 to 158°F (0 to 70°C)
Accuracy
(linearity,
hysteresis, repeatability)
Standard: ±0.25% of full
scale ±1 least significant digit
Option:
±0.1% full scale ±1 least significant digit
Option:
NIST traceable test report and data
Temperature Stability
(relative to 77°F
or 25°C)
±1% full scale for offset and span, 32 to
158°F (0 to 70°C) typical
Display
(update rate)
3 readings per second nominal display update
rate
Sensor
Piezoresistive sensor Custom 1C is
bonded to the
316 SS diaphragm. No moving parts mean stable readings,
low zero drift and long life to at least 1 million pressure cycles.
Competitors often use a bonded strain gauge, which tends
to drift resulting in less stable reading and repeatability problems
Auto Shutoff
(30 minutes
standard)