SPECIFICATIONS
Storage
temperature –40
to 203°F (–40 to 95°C)
Operating
temperature .
. . . . . . . . . . . . . . . . . . . . . . –4 to 185°F (–20 to 85°C)
Compensated
temperature .
. . . . . . . . . . . . . . . . . . . . . 32 to 158°F (0 to 70°C)
Accuracy
(linearity,
hysteresis, repeatability)
Standard:
±0.25% of full scale ±1 least significant digit
Option: ±0.1%
full scale ±1 least significant digit
Option:
NIST
traceable test report and data
Temperature
Stability
(relative
to 77°F or 25°C)
±1%
full scale for offset and span, 32 to 158°F (0 to 70°C) typical
Display
(update
rate)
3
readings per second nominal display update rate
Sensor Piezoresistive sensor Custom 1C is
bonded to the
316 SS diaphragm. No moving parts mean stable readings,
low zero drift and long life to at least 1 million pressure cycles.
Competitors often use a bonded strain gauge, which tends
to drift resulting in less stable reading and repeatability problems
Auto
Shutoff (30